CVE-2017-9658

UNKNOWN
Published 2018-04-30T15:00:00Z
Actions:

Expert Analysis

Professional remediation guidance

Get tailored security recommendations from our analyst team for CVE-2017-9658. We'll provide specific mitigation strategies based on your environment and risk profile.

No CVSS data available

Description

Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.

Available Exploits

No exploits available for this CVE.

Related News

No news articles found for this CVE.

Affected Products

GitHub Security Advisories

Community-driven vulnerability intelligence from GitHub

⚠ Unreviewed MODERATE

GHSA-ccgj-ph26-hf87

Advisory Details

Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.

CVSS Scoring

CVSS Score

5.0

CVSS Vector

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Advisory provided by GitHub Security Advisory Database. Published: May 13, 2022, Modified: May 13, 2022

References

Published: 2018-04-30T15:00:00Z
Last Modified: 2024-09-16T17:15:12.054Z