Loading HuntDB...

CVE-2018-8850

UNKNOWN
Published 2018-09-26T19:00:00Z
Actions:

Expert Analysis

Professional remediation guidance

Get tailored security recommendations from our analyst team for CVE-2018-8850. We'll provide specific mitigation strategies based on your environment and risk profile.

No CVSS data available

Description

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution.

Available Exploits

No exploits available for this CVE.

Related News

No news articles found for this CVE.

Affected Products

GitHub Security Advisories

Community-driven vulnerability intelligence from GitHub

⚠ Unreviewed CRITICAL

GHSA-f855-pprx-c8pg

Advisory Details

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution.

CVSS Scoring

CVSS Score

9.0

CVSS Vector

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Advisory provided by GitHub Security Advisory Database. Published: May 13, 2022, Modified: May 13, 2022

References

Published: 2018-09-26T19:00:00Z
Last Modified: 2024-09-17T01:15:54.816Z
Copied to clipboard!