Loading HuntDB...

CVE-2019-0040

MEDIUM
Published 2019-04-10T20:13:51.499559Z
Actions:

Expert Analysis

Professional remediation guidance

Get tailored security recommendations from our analyst team for CVE-2019-0040. We'll provide specific mitigation strategies based on your environment and risk profile.

CVSS Score

V3.0
6.5
/10
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L
Base Score Metrics
Exploitability: N/A Impact: N/A

EPSS Score

v2025.03.14
0.001
probability
of exploitation in the wild

There is a 0.1% chance that this vulnerability will be exploited in the wild within the next 30 days.

Updated: 2025-06-25
Exploit Probability
Percentile: 0.360
Higher than 36.0% of all CVEs

Attack Vector Metrics

Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED

Impact Metrics

Confidentiality
LOW
Integrity
NONE
Availability
LOW

Description

On Junos OS, rpcbind should only be listening to port 111 on the internal routing instance (IRI). External packets destined to port 111 should be dropped. Due to an information leak vulnerability, responses were being generated from the source address of the management interface (e.g. fxp0) thus disclosing internal addressing and existence of the management interface itself. A high rate of crafted packets destined to port 111 may also lead to a partial Denial of Service (DoS). Note: Systems with fxp0 disabled or unconfigured are not vulnerable to this issue. This issue only affects Junos OS releases based on FreeBSD 10 or higher (typically Junos OS 15.1+). Administrators can confirm whether systems are running a version of Junos OS based on FreeBSD 10 or higher by typing: user@junos> show version | match kernel JUNOS OS Kernel 64-bit [20181214.223829_fbsd-builder_stable_10] Affected releases are Juniper Networks Junos OS: 15.1 versions prior to 15.1F6-S12, 15.1R7-S4; 15.1X53 versions prior to 15.1X53-D236; 16.1 versions prior to 16.1R7-S1; 16.2 versions prior to 16.2R2-S9; 17.1 versions prior to 17.1R3; 17.2 versions prior to 17.2R1-S8; 17.3 versions prior to 17.3R2; 17.4 versions prior to 17.4R1-S1, 17.4R1-S7, 17.4R2. This issue does not affect Junos OS releases prior to 15.1.

Available Exploits

No exploits available for this CVE.

Related News

No news articles found for this CVE.

Affected Products

GitHub Security Advisories

Community-driven vulnerability intelligence from GitHub

⚠ Unreviewed CRITICAL

GHSA-99fv-28fj-8fh2

Advisory Details

On Junos OS, rpcbind should only be listening to port 111 on the internal routing instance (IRI). External packets destined to port 111 should be dropped. Due to an information leak vulnerability, responses were being generated from the source address of the management interface (e.g. fxp0) thus disclosing internal addressing and existence of the management interface itself. A high rate of crafted packets destined to port 111 may also lead to a partial Denial of Service (DoS). Note: Systems with fxp0 disabled or unconfigured are not vulnerable to this issue. This issue only affects Junos OS releases based on FreeBSD 10 or higher (typically Junos OS 15.1+). Administrators can confirm whether systems are running a version of Junos OS based on FreeBSD 10 or higher by typing: user@junos> show version | match kernel JUNOS OS Kernel 64-bit [20181214.223829_fbsd-builder_stable_10] Affected releases are Juniper Networks Junos OS: 15.1 versions prior to 15.1F6-S12, 15.1R7-S4; 15.1X53 versions prior to 15.1X53-D236; 16.1 versions prior to 16.1R7-S1; 16.2 versions prior to 16.2R2-S9; 17.1 versions prior to 17.1R3; 17.2 versions prior to 17.2R1-S8; 17.3 versions prior to 17.3R2; 17.4 versions prior to 17.4R1-S1, 17.4R1-S7, 17.4R2. This issue does not affect Junos OS releases prior to 15.1.

CVSS Scoring

CVSS Score

9.0

CVSS Vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

Advisory provided by GitHub Security Advisory Database. Published: May 13, 2022, Modified: May 13, 2022

References

Published: 2019-04-10T20:13:51.499559Z
Last Modified: 2024-09-16T19:00:02.889Z
Copied to clipboard!