Loading HuntDB...

CVE-2019-1606

MEDIUM
Published 2019-03-08T20:00:00Z
Actions:

Expert Analysis

Professional remediation guidance

Get tailored security recommendations from our analyst team for CVE-2019-1606. We'll provide specific mitigation strategies based on your environment and risk profile.

CVSS Score

V3.0
5.3
/10
CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Base Score Metrics
Exploitability: N/A Impact: N/A

EPSS Score

v2023.03.01
0.000
probability
of exploitation in the wild

There is a 0.0% chance that this vulnerability will be exploited in the wild within the next 30 days.

Updated: 2025-01-25
Exploit Probability
Percentile: 0.051
Higher than 5.1% of all CVEs

Attack Vector Metrics

Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
UNCHANGED

Impact Metrics

Confidentiality
LOW
Integrity
LOW
Availability
LOW

Description

A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid user credentials to exploit this vulnerability. Nexus 3000, 3500, and Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I7(4).

Available Exploits

No exploits available for this CVE.

Related News

No news articles found for this CVE.

Affected Products

GitHub Security Advisories

Community-driven vulnerability intelligence from GitHub

⚠ Unreviewed HIGH

GHSA-f98f-97pg-74wc

Advisory Details

A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid user credentials to exploit this vulnerability. Nexus 3000, 3500, and Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I7(4).

CVSS Scoring

CVSS Score

7.5

CVSS Vector

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Advisory provided by GitHub Security Advisory Database. Published: May 13, 2022, Modified: May 13, 2022

References

Published: 2019-03-08T20:00:00Z
Last Modified: 2024-11-21T19:43:51.932Z
Copied to clipboard!