Description
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
Understanding This Vulnerability
This Common Vulnerabilities and Exposures (CVE) entry provides detailed information about a security vulnerability that has been publicly disclosed. CVEs are standardized identifiers assigned by MITRE Corporation to track and catalog security vulnerabilities across software and hardware products.
The severity rating (HIGH) indicates the potential impact of this vulnerability based on the CVSS (Common Vulnerability Scoring System) framework. Higher severity ratings typically indicate vulnerabilities that could lead to more significant security breaches if exploited. Security teams should prioritize remediation efforts based on severity, exploit availability, and the EPSS (Exploit Prediction Scoring System) score, which predicts the likelihood of exploitation in the wild.
If this vulnerability affects products or systems in your infrastructure, we recommend reviewing the affected products section, checking for available patches or updates from vendors, and implementing recommended workarounds or solutions until a permanent fix is available. Organizations should also monitor security advisories and threat intelligence feeds for updates about active exploitation of this vulnerability.