Loading HuntDB...

CVE-2023-22392

MEDIUM
Published 2023-10-12T22:55:42.016Z
Actions:

Expert Analysis

Professional remediation guidance

Get tailored security recommendations from our analyst team for CVE-2023-22392. We'll provide specific mitigation strategies based on your environment and risk profile.

CVSS Score

V3.1
6.5
/10
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Base Score Metrics
Exploitability: N/A Impact: N/A

EPSS Score

v2025.03.14
0.001
probability
of exploitation in the wild

There is a 0.1% chance that this vulnerability will be exploited in the wild within the next 30 days.

Updated: 2025-06-25
Exploit Probability
Percentile: 0.207
Higher than 20.7% of all CVEs

Attack Vector Metrics

Attack Vector
ADJACENT_NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED

Impact Metrics

Confidentiality
NONE
Integrity
NONE
Availability
HIGH

Description


A Missing Release of Memory after Effective Lifetime vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS).

PTX3000, PTX5000, QFX10000, PTX1000, PTX10002, and PTX10004, PTX10008 and PTX10016 with LC110x FPCs do not support certain flow-routes. Once a flow-route is received over an established BGP session and an attempt is made to install the resulting filter into the PFE, FPC heap memory is leaked. The FPC heap memory can be monitored using the CLI command "show chassis fpc".

The following syslog messages can be observed if the respective filter derived from a flow-route cannot be installed.

expr_dfw_sfm_range_add:661 SFM packet-length Unable to get a sfm entry for updating the hw
expr_dfw_hw_sfm_add:750 Unable to add the filter secondarymatch to the hardware
expr_dfw_base_hw_add:52 Failed to add h/w sfm data.
expr_dfw_base_hw_create:114 Failed to add h/w data.
expr_dfw_base_pfe_inst_create:241 Failed to create base inst for sfilter 0 on PFE 0 for __flowspec_default_inet__
expr_dfw_flt_inst_change:1368 Failed to create __flowspec_default_inet__ on PFE 0
expr_dfw_hw_pgm_fnum:465 dfw_pfe_inst_old not found for pfe_index 0!
expr_dfw_bp_pgm_flt_num:548 Failed to pgm bind-point in hw: generic failure
expr_dfw_bp_topo_handler:1102 Failed to program fnum.
expr_dfw_entry_process_change:679 Failed to change instance for filter __flowspec_default_inet__.
This issue affects Juniper Networks Junos OS:

on PTX1000, PTX10002, and PTX10004, PTX10008 and PTX10016 with LC110x FPCs:

* All versions prior to 20.4R3-S5;
* 21.1 versions prior to 21.1R3-S4;
* 21.2 versions prior to 21.2R3-S2;
* 21.3 versions prior to 21.3R3;
* 21.4 versions prior to 21.4R2-S2, 21.4R3;
* 22.1 versions prior to 22.1R1-S2, 22.1R2.

on PTX3000, PTX5000, QFX10000:

* All versions prior to 20.4R3-S8;
* 21.1 version 21.1R1 and later versions;
* 21.2 versions prior to 21.2R3-S6;
* 21.3 versions prior to 21.3R3-S5;
* 21.4 versions prior to 21.4R3-S4;
* 22.1 versions prior to 22.1R3-S3
* 22.2 versions prior to 22.2R3-S1
* 22.3 versions prior to 22.3R2-S2, 22.3R3
* 22.4 versions prior to 22.4R2.

Available Exploits

No exploits available for this CVE.

Related News

No news articles found for this CVE.

Affected Products

GitHub Security Advisories

Community-driven vulnerability intelligence from GitHub

⚠ Unreviewed MODERATE

GHSA-rfgp-826j-vp9f

Advisory Details

A Missing Release of Memory after Effective Lifetime vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS). PTX3000, PTX5000, QFX10000, PTX1000, PTX10002, and PTX10004, PTX10008 and PTX10016 with LC110x FPCs do not support certain flow-routes. Once a flow-route is received over an established BGP session and an attempt is made to install the resulting filter into the PFE, FPC heap memory is leaked. The FPC heap memory can be monitored using the CLI command "show chassis fpc". The following syslog messages can be observed if the respective filter derived from a flow-route cannot be installed. expr_dfw_sfm_range_add:661 SFM packet-length Unable to get a sfm entry for updating the hw expr_dfw_hw_sfm_add:750 Unable to add the filter secondarymatch to the hardware expr_dfw_base_hw_add:52 Failed to add h/w sfm data. expr_dfw_base_hw_create:114 Failed to add h/w data. expr_dfw_base_pfe_inst_create:241 Failed to create base inst for sfilter 0 on PFE 0 for __flowspec_default_inet__ expr_dfw_flt_inst_change:1368 Failed to create __flowspec_default_inet__ on PFE 0 expr_dfw_hw_pgm_fnum:465 dfw_pfe_inst_old not found for pfe_index 0! expr_dfw_bp_pgm_flt_num:548 Failed to pgm bind-point in hw: generic failure expr_dfw_bp_topo_handler:1102 Failed to program fnum. expr_dfw_entry_process_change:679 Failed to change instance for filter __flowspec_default_inet__. This issue affects Juniper Networks Junos OS: on PTX1000, PTX10002, and PTX10004, PTX10008 and PTX10016 with LC110x FPCs: * All versions prior to 20.4R3-S5; * 21.1 versions prior to 21.1R3-S4; * 21.2 versions prior to 21.2R3-S2; * 21.3 versions prior to 21.3R3; * 21.4 versions prior to 21.4R2-S2, 21.4R3; * 22.1 versions prior to 22.1R1-S2, 22.1R2. on PTX3000, PTX5000, QFX10000: * All versions prior to 20.4R3-S8; * 21.1 version 21.1R1 and later versions; * 21.2 versions prior to 21.2R3-S6; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S4; * 22.1 versions prior to 22.1R3-S3 * 22.2 versions prior to 22.2R3-S1 * 22.3 versions prior to 22.3R2-S2, 22.3R3 * 22.4 versions prior to 22.4R2.

CVSS Scoring

CVSS Score

5.0

CVSS Vector

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Advisory provided by GitHub Security Advisory Database. Published: October 13, 2023, Modified: February 21, 2024

References

Published: 2023-10-12T22:55:42.016Z
Last Modified: 2024-08-02T10:07:06.639Z
Copied to clipboard!