Loading HuntDB...

CVE-2023-39466

MEDIUM
Published 2024-05-03T01:59:28.811Z
Actions:

Expert Analysis

Professional remediation guidance

Get tailored security recommendations from our analyst team for CVE-2023-39466. We'll provide specific mitigation strategies based on your environment and risk profile.

CVSS Score

V3.0
5.3
/10
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Base Score Metrics
Exploitability: N/A Impact: N/A

EPSS Score

v2025.03.14
0.001
probability
of exploitation in the wild

There is a 0.1% chance that this vulnerability will be exploited in the wild within the next 30 days.

Updated: 2025-06-25
Exploit Probability
Percentile: 0.253
Higher than 25.3% of all CVEs

Attack Vector Metrics

Attack Vector
Not Available
Attack Complexity
Not Available
Privileges Required
Not Available
User Interaction
Not Available
Scope
Not Available

Impact Metrics

Confidentiality
Not Available
Integrity
Not Available
Availability
Not Available

Description

Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.

The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797.

Available Exploits

No exploits available for this CVE.

Related News

No news articles found for this CVE.

Affected Products

GitHub Security Advisories

Community-driven vulnerability intelligence from GitHub

⚠ Unreviewed MODERATE

GHSA-8vq2-42cx-f687

Advisory Details

Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797.

CVSS Scoring

CVSS Score

5.0

CVSS Vector

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Advisory provided by GitHub Security Advisory Database. Published: May 3, 2024, Modified: May 3, 2024

References

Published: 2024-05-03T01:59:28.811Z
Last Modified: 2024-08-02T18:10:20.933Z
Copied to clipboard!