Loading HuntDB...

CVE-2024-10771

HIGH
Published 2024-12-06T12:24:40.610Z
Actions:

Expert Analysis

Professional remediation guidance

Get tailored security recommendations from our analyst team for CVE-2024-10771. We'll provide specific mitigation strategies based on your environment and risk profile.

CVSS Score

V3.1
8.8
/10
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Base Score Metrics
Exploitability: N/A Impact: N/A

EPSS Score

v2025.03.14
0.008
probability
of exploitation in the wild

There is a 0.8% chance that this vulnerability will be exploited in the wild within the next 30 days.

Updated: 2025-06-25
Exploit Probability
Percentile: 0.728
Higher than 72.8% of all CVEs

Attack Vector Metrics

Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
UNCHANGED

Impact Metrics

Confidentiality
HIGH
Integrity
HIGH
Availability
HIGH

Description

Due to missing input validation during one step of the firmware update process, the product
is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker
can execute arbitrary system commands in the root user’s contexts.

Understanding This Vulnerability

This Common Vulnerabilities and Exposures (CVE) entry provides detailed information about a security vulnerability that has been publicly disclosed. CVEs are standardized identifiers assigned by MITRE Corporation to track and catalog security vulnerabilities across software and hardware products.

The severity rating (HIGH) indicates the potential impact of this vulnerability based on the CVSS (Common Vulnerability Scoring System) framework. Higher severity ratings typically indicate vulnerabilities that could lead to more significant security breaches if exploited. Security teams should prioritize remediation efforts based on severity, exploit availability, and the EPSS (Exploit Prediction Scoring System) score, which predicts the likelihood of exploitation in the wild.

If this vulnerability affects products or systems in your infrastructure, we recommend reviewing the affected products section, checking for available patches or updates from vendors, and implementing recommended workarounds or solutions until a permanent fix is available. Organizations should also monitor security advisories and threat intelligence feeds for updates about active exploitation of this vulnerability.

Available Exploits

No exploits available for this CVE.

Related News

No news articles found for this CVE.

Affected Products

References

Workarounds

For TiM3xx: 

We recommend updating the firmware only in a trusted environment.

Solutions

For InspectorP61x and InspectorP62x: Customers are strongly recommended to upgrade to the latest release.

Credits & Acknowledgments

finder

Manuel Stotz

finder

Tobias Jaeger

EU Vulnerability Database

Monitored by ENISA for EU cybersecurity

EU Coordination

EU Coordinated

Exploitation Status

No Known Exploitation

ENISA Analysis

Malicious code in bioql (PyPI)

Affected Products (ENISA)

sick ag
sick inspectorp62x

ENISA Scoring

CVSS Score (3.1)

8.8
/10
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

EPSS Score

1.530
probability

Data provided by ENISA EU Vulnerability Database. Last updated: October 3, 2025

GitHub Security Advisories

Community-driven vulnerability intelligence from GitHub

⚠ Unreviewed HIGH

GHSA-252q-qph8-r7q3

Advisory Details

Due to missing input validation during one step of the firmware update process, the product is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker can execute arbitrary system commands in the root user’s contexts.

CVSS Scoring

CVSS Score

7.5

CVSS Vector

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Advisory provided by GitHub Security Advisory Database. Published: December 6, 2024, Modified: December 6, 2024

References

Published: 2024-12-06T12:24:40.610Z
Last Modified: 2024-12-09T14:47:30.064Z
Copied to clipboard!