Loading HuntDB...

CVE-2024-1573

MEDIUM
Published 2024-07-04T08:59:44.079Z
Actions:

Expert Analysis

Professional remediation guidance

Get tailored security recommendations from our analyst team for CVE-2024-1573. We'll provide specific mitigation strategies based on your environment and risk profile.

CVSS Score

V3.1
5.9
/10
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
Base Score Metrics
Exploitability: N/A Impact: N/A

EPSS Score

v2025.03.14
0.001
probability
of exploitation in the wild

There is a 0.1% chance that this vulnerability will be exploited in the wild within the next 30 days.

Updated: 2025-06-25
Exploit Probability
Percentile: 0.231
Higher than 23.1% of all CVEs

Attack Vector Metrics

Attack Vector
NETWORK
Attack Complexity
HIGH
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED

Impact Metrics

Confidentiality
NONE
Integrity
HIGH
Availability
NONE

Description

Improper Authentication vulnerability in the mobile monitoring feature of ICONICS GENESIS64 versions 10.97 to 10.97.2, Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.2 and Mitsubishi Electric MC Works64 all versions allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: * Active Directory is used in the security setting.
* “Automatic log in” option is enabled in the security setting.
* The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account.
* The IcoAnyGlass IIS Application Pool account is included in GENESIS64TM and MC Works64 Security and has permission to log in.

Available Exploits

No exploits available for this CVE.

Related News

No news articles found for this CVE.

Affected Products

GitHub Security Advisories

Community-driven vulnerability intelligence from GitHub

⚠ Unreviewed MODERATE

GHSA-34qf-4246-phgf

Advisory Details

Improper Authentication vulnerability in the mobile monitoring feature of ICONICS GENESIS64 versions 10.97 to 10.97.2, Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.2 and Mitsubishi Electric MC Works64 all versions allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: * Active Directory is used in the security setting. * “Automatic log in” option is enabled in the security setting. * The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. * The IcoAnyGlass IIS Application Pool account is included in GENESIS64TM and MC Works64 Security and has permission to log in.

CVSS Scoring

CVSS Score

5.0

CVSS Vector

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N

Advisory provided by GitHub Security Advisory Database. Published: July 4, 2024, Modified: July 4, 2024

References

Published: 2024-07-04T08:59:44.079Z
Last Modified: 2024-08-01T18:40:21.409Z
Copied to clipboard!