Loading HuntDB...

CVE-2024-54005

MEDIUM
Published 2024-12-10T13:54:15.994Z
Actions:

Expert Analysis

Professional remediation guidance

Get tailored security recommendations from our analyst team for CVE-2024-54005. We'll provide specific mitigation strategies based on your environment and risk profile.

CVSS Score

V3.1
5.1
/10
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
Base Score Metrics
Exploitability: N/A Impact: N/A

EPSS Score

v2025.03.14
0.000
probability
of exploitation in the wild

There is a 0.0% chance that this vulnerability will be exploited in the wild within the next 30 days.

Updated: 2025-06-25
Exploit Probability
Percentile: 0.016
Higher than 1.6% of all CVEs

Attack Vector Metrics

Attack Vector
Not Available
Attack Complexity
Not Available
Privileges Required
Not Available
User Interaction
Not Available
Scope
Not Available

Impact Metrics

Confidentiality
Not Available
Integrity
Not Available
Availability
Not Available

Description

A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems.

Available Exploits

No exploits available for this CVE.

Related News

No news articles found for this CVE.

Affected Products

GitHub Security Advisories

Community-driven vulnerability intelligence from GitHub

⚠ Unreviewed MODERATE

GHSA-w23f-22px-mx2g

Advisory Details

A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems.

CVSS Scoring

CVSS Score

5.0

CVSS Vector

CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N

Advisory provided by GitHub Security Advisory Database. Published: December 10, 2024, Modified: December 10, 2024

References

Published: 2024-12-10T13:54:15.994Z
Last Modified: 2024-12-10T17:17:46.788Z
Copied to clipboard!