Loading HuntDB...

Vulnerabilities

CVE-2024-50377

MEDIUM

A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.

Published Nov 26, 2024

CVE-2024-50376

HIGH

A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.

Published Nov 26, 2024

CVE-2024-50375

CRITICAL

A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.

Published Nov 26, 2024

CVE-2024-50374

CRITICAL

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.

Published Nov 26, 2024

CVE-2024-50373

CRITICAL

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.

Published Nov 26, 2024

CVE-2024-50372

CRITICAL

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.

Published Nov 26, 2024

CVE-2024-50371

CRITICAL

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.

Published Nov 26, 2024

CVE-2024-50370

CRITICAL

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.

Published Nov 26, 2024

CVE-2024-50369

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50368

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50367

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50366

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50365

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50364

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50363

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50362

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "connection_profile_apply" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50361

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "certificate_file_remove" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50360

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "snmp_apply" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50359

HIGH

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands.

Published Nov 26, 2024

CVE-2024-50358

HIGH

A CWE-15 "External Control of System or Configuration Setting" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.

Published Nov 26, 2024

CVE-2023-52335

HIGH

Advantech iView ConfigurationServlet SQL Injection Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Advantech iView. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ConfigurationServlet servlet, which listens on TCP port 8080 by default. When parsing the column_value element, the process does not properly validate a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-17863.

Published Nov 22, 2024

CVE-2024-39364

MEDIUM

Advantech ADAM-5630 has built-in commands that can be executed without authenticating the user. These commands allow for restarting the operating system, rebooting the hardware, and stopping the execution. The commands can be sent to a simple HTTP request and are executed by the device automatically, without discrimination of origin or level of privileges of the user sending the commands.

Published Sep 27, 2024

CVE-2024-34542

MEDIUM

Advantech ADAM-5630 shares user credentials plain text between the device and the user source device during the login process.

Published Sep 27, 2024

CVE-2024-28948

HIGH

Advantech ADAM-5630 contains a cross-site request forgery (CSRF) vulnerability. It allows an attacker to partly circumvent the same origin policy, which is designed to prevent different websites from interfering with each other.

Published Sep 27, 2024

CVE-2024-39275

HIGH

Cookies of authenticated Advantech ADAM-5630 users remain as active valid cookies when a session is closed. Forging requests with a legitimate cookie, even if the session was terminated, allows an unauthorized attacker to act with the same level of privileges of the legitimate user.

Published Sep 27, 2024

CVE-2024-38308

HIGH

Advantech ADAM 5550's web application includes a "logs" page where all the HTTP requests received are displayed to the user. The device doesn't correctly neutralize malicious code when parsing HTTP requests to generate page output.

Published Sep 27, 2024

CVE-2024-37187

MEDIUM

Advantech ADAM-5550 share user credentials with a low level of encryption, consisting of base 64 encoding.

Published Sep 27, 2024

CVE-2024-2453

MEDIUM

There is an SQL injection vulnerability in Advantech WebAccess/SCADA software that allows an authenticated attacker to remotely inject SQL code in the database. Successful exploitation of this vulnerability could allow an attacker to read or modify data on the remote database.

Published Mar 21, 2024

CVE-2023-5642

CRITICAL

Advantech R-SeeNet v2.4.23 allows an unauthenticated remote attacker to read from and write to the snmpmon.ini file, which contains sensitive information.

Published Oct 18, 2023

CVE-2023-4215

MEDIUM

Advantech WebAccess version 9.1.3 contains an exposure of sensitive information to an unauthorized actor vulnerability that could leak user credentials.

Published Oct 16, 2023

CVE-2023-4203

CRITICAL

Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stored Cross-Site Scripting vulnerability, which can be triggered by authenticated users in the ping tool of the web-interface.

Published Aug 08, 2023

CVE-2023-4202

CRITICAL

Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stored Cross-Site Scripting vulnerability, which can be triggered by authenticated users in the device name field of the web-interface.

Published Aug 08, 2023

CVE-2023-1437

CRITICAL

All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files.

Published Aug 02, 2023

CVE-2023-2611

CRITICAL

Advantech R-SeeNet versions 2.4.22 is installed with a hidden root-level user that is not available in the users list. This hidden user has a password that cannot be changed by users.

Published Jun 22, 2023

CVE-2023-3256

HIGH

Advantech R-SeeNet versions 2.4.22 allows low-level users to access and load the content of local files.

Published Jun 22, 2023

CVE-2023-2866

HIGH

If an attacker can trick an authenticated user into loading a maliciously crafted .zip file onto Advantech WebAccess version 8.4.5, a web shell could be used to give the attacker full control of the SCADA server.

Published Jun 07, 2023

CVE-2023-22450

HIGH

In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to upload an ASP script file to a webserver when logged in as manager user, which can lead to arbitrary code execution.

Published Jun 05, 2023

CVE-2023-32540

HIGH

In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an attacker to overwrite any file in the operating system (including system files), inject code into an XLS file, and modify the file extension, which could lead to arbitrary code execution.

Published Jun 05, 2023

CVE-2023-32628

HIGH

In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to modify the file extension of a certificate file to ASP when uploading it, which can lead to remote code execution.

Published Jun 05, 2023

CVE-2023-2573

HIGH

Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by an command injection vulnerability in the NTP server input field, which can be triggered by authenticated users via a crafted POST request.

Published May 08, 2023

CVE-2023-2574

HIGH

Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by an command injection vulnerability in the device name input field, which can be triggered by authenticated users via a crafted POST request.

Published May 08, 2023

CVE-2023-2575

HIGH

Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stack-based Buffer Overflow vulnerability, which can be triggered by authenticated users via a crafted POST request.

Published May 08, 2023

CVE-2022-3387

MEDIUM

Advantech R-SeeNet Versions 2.4.19 and prior are vulnerable to path traversal attacks. An unauthorized attacker could remotely exploit vulnerable PHP code to delete .PDF files.

Published Oct 27, 2022

CVE-2022-3386

CRITICAL

Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can use an outsized filename to overflow the stack buffer and enable remote code execution.

Published Oct 27, 2022

CVE-2022-3385

CRITICAL

Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can remotely overflow the stack buffer and enable remote code execution.

Published Oct 27, 2022

CVE-2022-22987

CRITICAL

The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.

Published Feb 04, 2022

CVE-2021-42703

MEDIUM

This vulnerability could allow an attacker to send malicious Javascript code resulting in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage, and performing unintended browser action.

Published Nov 15, 2021

CVE-2021-42706

HIGH

This vulnerability could allow an attacker to disclose information and execute arbitrary code on affected installations of WebAccess/MHI Designer

Published Nov 15, 2021

CVE-2021-32951

MEDIUM

WebAccess/NMS (Versions prior to v3.0.3_Build6299) has an improper authentication vulnerability, which may allow unauthorized users to view resources monitored and controlled by the WebAccess/NMS, as well as IP addresses and names of all the devices managed via WebAccess/NMS.

Published Oct 27, 2021

CVE-2021-38389

CRITICAL

Advantech WebAccess versions 9.02 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute code.

Published Oct 18, 2021