Loading HuntDB...

Vulnerabilities

CVE-2024-24377

UNKNOWN

An issue in idocv v.14.1.3_20231228 allows a remote attacker to execute arbitrary code and obtain sensitive information via a crafted script.

Published Feb 16, 2024

CVE-2023-6926

HIGH

There is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access.

Published Jan 23, 2024

CVE-2023-38405

UNKNOWN

On Crestron 3-Series Control Systems before 1.8001.0187, crafting and sending a specific BACnet packet can cause a crash.

Published Jul 17, 2023

CVE-2019-3939

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.

Published Apr 30, 2019

CVE-2019-3938

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.

Published Apr 30, 2019

CVE-2019-3937

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data.

Published Apr 30, 2019

CVE-2019-3936

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a "stopped" state. A remote, unauthenticated attacker can use this vulnerability to stop an active slideshow.

Published Apr 30, 2019

CVE-2019-3935

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows.

Published Apr 30, 2019

CVE-2019-3934

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code.

Published Apr 30, 2019

CVE-2019-3933

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code.

Published Apr 30, 2019

CVE-2019-3932

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.

Published Apr 30, 2019

CVE-2019-3931

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root.

Published Apr 30, 2019

CVE-2019-3930

UNKNOWN

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint.

Published Apr 30, 2019

CVE-2019-3929

UNKNOWN

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.

Published Apr 30, 2019

CVE-2019-3928

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter.

Published Apr 30, 2019

CVE-2019-3927

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user's password and gain access to restricted areas on the HTTP interface.

Published Apr 30, 2019

CVE-2019-3926

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.14.1. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.

Published Apr 30, 2019

CVE-2019-3925

UNKNOWN

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.

Published Apr 30, 2019

CVE-2018-5553

CRITICAL

The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.

Published Jul 10, 2018