Vulnerabilities
CVE-2024-9929
MEDIUMA vulnerability exists in NSD570 that allows any authenticated user to access all device logs disclosing login information with timestamps.
CVE-2024-9928
MEDIUMA vulnerability exists in NSD570 login panel that does not restrict excessive authentication attempts. If exploited, this could cause account takeover and unauthorized access to the system when an attacker conducts brute-force attacks against the equipment login. Note that the system supports only one concurrent session and implements a delay of more than a second between failed login attempts making it difficult to automate the attacks.
CVE-2024-41156
LOWProfile files from TRO600 series radios are extracted in plain-text and encrypted file formats. Profile files provide potential attackers valuable configuration information about the Tropos network. Profiles can only be exported by authenticated users with higher privilege of write access.
CVE-2024-41153
HIGHCommand injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the web UI can execute commands on the device with root privileges, far more extensive than what the write privilege intends.
CVE-2024-7941
MEDIUMAn HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. By modifying the URL value to a malicious site, an attacker may successfully launch a phishing scam and steal user credentials.
CVE-2024-7940
HIGHThe product exposes a service that is intended for local only to all network interfaces without any authentication.
CVE-2024-3982
HIGHAn attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level is not enabled and only users with administrator rights can enable it.
CVE-2024-3980
CRITICALThe MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application.
CVE-2024-4872
CRITICALA vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential.
CVE-2024-28020
HIGHA user/password reuse vulnerability exists in the FOXMAN-UN/UNEM application and server management. If exploited a malicious high-privileged user could use the passwords and login information through complex routines to extend access on the server and other services.
CVE-2024-28024
MEDIUMA vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is stored in cleartext within a resource that might be accessible to another control sphere.
CVE-2024-28022
MEDIUMA vulnerability exists in the UNEM server / APIGateway that if exploited allows a malicious user to perform an arbitrary number of authentication attempts using different passwords, and eventually gain access to other components in the same security realm using the targeted account.
CVE-2024-28023
MEDIUMA vulnerability exists in the message queueing mechanism that if exploited can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or even execute arbitrary code.
CVE-2024-28021
HIGHA vulnerability exists in the FOXMAN-UN/UNEM server that affects the message queueing mechanism’s certificate validation. If exploited an attacker could spoof a trusted entity causing a loss of confidentiality and integrity.
CVE-2024-2011
HIGHA heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that if exploited will generally lead to a denial of service but can be used to execute arbitrary code, which is usually outside the scope of a program's implicit security policy
CVE-2024-2012
CRITICALvulnerability exists in the FOXMAN-UN/UNEM server / API Gateway that if exploited an attacker could use to allow unintended commands or code to be executed on the UNEM server allowing sensitive data to be read or modified or could cause other unintended behavior
CVE-2024-2013
CRITICALAn authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway component that if exploited allows attackers without any access to interact with the services and the post-authentication attack surface.
CVE-2024-2461
UNKNOWNIf exploited an attacker could traverse the file system to access files or directories that would otherwise be inaccessible
CVE-2024-2462
UNKNOWNAllow attackers to intercept or falsify data exchanges between the client and the server
CVE-2024-2378
HIGHA vulnerability exists in the web-authentication component of the SDM600. If exploited an attacker could escalate privileges on af-fected installations.
CVE-2024-2617
HIGHA vulnerability exists in the RTU500 that allows for authenticated and authorized users to bypass secure update. If a malicious actor successfully exploits this vulnerability, they could use it to update the RTU500 with unsigned firmware.
CVE-2024-2377
HIGHA vulnerability exists in the too permissive HTTP response header web server settings of the SDM600. An attacker can take advantage of this and possibly carry out privileged actions and access sensitive information.
CVE-2024-2097
HIGHAuthenticated List control client can execute the LINQ query in SCM Server to present event as list for operator. An authenticated malicious client can send special LINQ query to execute arbitrary code remotely (RCE) on the SCM Server that an attacker otherwise does not have authorization to do.
CVE-2024-0400
HIGHSCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability.
CVE-2024-1532
MEDIUMA vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below. A malicious actor could enforce diagnostic texts being displayed as empty strings, if an authorized user uploads a specially crafted stb-language file.
CVE-2024-1531
HIGHA vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below. A malicious actor could print random memory content in the RTU500 system log, if an authorized user uploads a specially crafted stb-language file.
CVE-2024-2244
MEDIUMREST service authentication anomaly with “valid username/no password” credential combination for batch job processing resulting in successful service invocation. The anomaly doesn’t exist with other credential combinations.
CVE-2022-3864
MEDIUMA vulnerability exists in the Relion update package signature validation. A tampered update package could cause the IED to restart. After restart the device is back to normal operation. An attacker could exploit the vulnerability by first gaining access to the system with security privileges and attempt to update the IED with a malicious update package. Successful exploitation of this vulnerability will cause the IED to restart, causing a temporary Denial of Service.
CVE-2022-2081
HIGHA vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function.
CVE-2023-6711
MEDIUMVulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Specially crafted messages sent to the mentioned components are not validated properly and can result in buffer overflow and as final consequence to a reboot of an RTU500 CMU.
CVE-2023-1514
HIGHA vulnerability exists in the component RTU500 Scripting interface. When a client connects to a server using TLS, the server presents a certificate. This certificate links a public key to the identity of the service and is signed by a Certification Authority (CA), allowing the client to validate that the remote service can be trusted and is not malicious. If the client does not validate the parameters of the certificate, then attackers could be able to spoof the identity of the service. An attacker could exploit the vulnerability by using faking the identity of a RTU500 device and intercepting the messages initiated via the RTU500 Scripting interface.
CVE-2023-5769
MEDIUMA vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to user input being improperly sanitized.
CVE-2023-5768
MEDIUMA vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again.
CVE-2023-5767
MEDIUMA vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to an RDT language file being improperly sanitized.
CVE-2023-4518
MEDIUMA vulnerability exists in the input validation of the GOOSE messages where out of range values received and processed by the IED caused a reboot of the device. In order for an attacker to exploit the vulnerability, goose receiving blocks need to be configured.
CVE-2023-5516
MEDIUMPoorly constructed webap requests and URI components with special characters trigger unhandled errors and exceptions, disclosing information about the underlying technology and other sensitive information details. The website unintentionally reveals sensitive information including technical details like version Info, endpoints, backend server, Internal IP. etc., which can potentially expose additional attack surface containing other interesting vulnerabilities.
CVE-2023-5515
MEDIUMThe responses for web queries with certain parameters disclose internal path of resources. This information can be used to learn internal structure of the application and to further plot attacks against web servers and deployed web applications.
CVE-2023-5514
MEDIUMThe response messages received from the eSOMS report generation using certain parameter queries with full file path can be abused for enumerating the local file system structure.
CVE-2023-2622
LOWAuthenticated clients can read arbitrary files on the MAIN Computer system using the remote procedure call (RPC) of the InspectSetup service endpoint. The low privilege client is then allowed to read arbitrary files that they do not have authorization to read.
CVE-2023-2621
MEDIUMThe McFeeder server (distributed as part of SSW package), is susceptible to an arbitrary file write vulnerability on the MAIN computer system. This vulnerability stems from the use of an outdated version of a third-party library, which is used to extract archives uploaded to McFeeder server. An authenticated malicious client can exploit this vulnerability by uploading a crafted ZIP archive via the network to McFeeder’s service endpoint.
CVE-2023-4816
MEDIUMA vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. This vulnerability can be exploited by an authenticated user per-forming an Equipment Tag Out holder action (Accept, Release, and Clear) for another user and entering an arbitrary password in the holder action confirmation dialog box. Despite entering an arbitrary password in the confirmation box, the system will execute the selected holder action.
CVE-2022-4608
HIGHA vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.
CVE-2022-2502
HIGHA vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function.
CVE-2023-2625
CRITICALA vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment as the CoreTec 4, having any level of access VIEWER to ADMIN. To exploit the vulnerability the attacker can inject shell commands through a particular field of the web user interface that will be executed by the system.
CVE-2023-1711
MEDIUMA vulnerability exists in a FOXMAN-UN and UNEM logging component, it only affects systems that use remote authentication to the network elements. If exploited an attacker could obtain confidential information. List of CPEs: * cpe:2.3:a:hitachienergy:foxman_un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman_un:R16A:*:*:*:*:*:*:* * * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy: unem :R16A:*:*:*:*:*:*:*
CVE-2022-3685
HIGHA vulnerability exists in the SDM600 software. The software operates at a privilege level that is higher than the minimum level required. An attacker who successfully exploits this vulnerability can escalate privileges. This issue affects: All SDM600 versions prior to version 1.3.0. List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.3.0.1339:*:*:*:*:*:*:*
CVE-2022-3686
MEDIUMA vulnerability exists in a SDM600 endpoint. An attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive. This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291) List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*
CVE-2022-3684
HIGHA vulnerability exists in a SDM600 endpoint. An attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive. This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291) List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*
CVE-2022-3683
HIGHA vulnerability exists in the SDM600 API web services authorization validation implementation. An attacker who successfully exploits the vulnerability could read data directly from a data store that is not restricted, or insufficiently protected, having access to sensitive data. This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291) List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*
CVE-2022-3682
CRITICALA vulnerability exists in the SDM600 file permission validation. An attacker could exploit the vulnerability by gaining access to the system and uploading a specially crafted message to the system node, which could result in Arbitrary code Executing. This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291) List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.182:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.342:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.447:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.481:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.506:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.566:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.20000.3174:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.291:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.931:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.21000.105:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.23000.291:*:*:*:*:*:*:*