Saia PG5 Controls Suite

1 Version 7 CVEs

Recent CVEs

CVE-2023-51605

Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18644.

MEDIUM May 03, 2024

CVE-2023-51604

Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18593.

MEDIUM May 03, 2024

CVE-2023-51603

Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18592.

HIGH May 03, 2024

CVE-2023-51602

Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18591.

MEDIUM May 03, 2024

CVE-2023-51601

Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of xml files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18563.

MEDIUM May 03, 2024

CVE-2023-51600

Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18456.

MEDIUM May 03, 2024

CVE-2023-51599

Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18412.

HIGH May 03, 2024