Known Vulnerabilities
CVE-2023-44199
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on MX Series allows a network-based, unauthenticated attacker to cause a Denial of Service (DoS). On Junos MX Series platforms with Precision Time Protocol (PTP) configured, a prolonged routing protocol churn can lead to an FPC crash and restart. This issue affects Juniper Networks Junos OS on MX Series: * All versions prior to 20.4R3-S4; * 21.1 version 21.1R1 and later versions; * 21.2 versions prior to 21.2R3-S2; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3; * 22.1 versions prior to 22.1R3; * 22.2 versions prior to 22.2R1-S1, 22.2R2.
CVE-2023-36843
An Improper Handling of Inconsistent Special Elements vulnerability in the Junos Services Framework (jsf) module of Juniper Networks Junos OS allows an unauthenticated network based attacker to cause a crash in the Packet Forwarding Engine (pfe) and thereby resulting in a Denial of Service (DoS). Upon receiving malformed SSL traffic, the PFE crashes. A manual restart will be needed to recover the device. This issue only affects devices with Juniper Networks Advanced Threat Prevention (ATP) Cloud enabled with Encrypted Traffic Insights (configured via ‘security-metadata-streaming policy’). This issue affects Juniper Networks Junos OS: * All versions prior to 20.4R3-S8, 20.4R3-S9; * 21.1 version 21.1R1 and later versions; * 21.2 versions prior to 21.2R3-S6; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S5; * 22.1 versions prior to 22.1R3-S4; * 22.2 versions prior to 22.2R3-S2; * 22.3 versions prior to 22.3R2-S2, 22.3R3; * 22.4 versions prior to 22.4R2-S1, 22.4R3;
CVE-2023-36841
An Improper Check for Unusual or Exceptional Conditions vulnerability in the Packet Forwarding Engine (pfe) of Juniper Networks Junos OS on MX Series allows a unauthenticated network-based attacker to cause an infinite loop, resulting in a Denial of Service (DoS). An attacker who sends malformed TCP traffic via an interface configured with PPPoE, causes an infinite loop on the respective PFE. This results in consuming all resources and a manual restart is needed to recover. This issue affects interfaces with PPPoE configured and tcp-mss enabled. This issue affects Juniper Networks Junos OS * All versions prior to 20.4R3-S7; * 21.1 version 21.1R1 and later versions; * 21.2 versions prior to 21.2R3-S6; * 21.3 versions prior to 21.3R3-S5; * 21.4 versions prior to 21.4R3-S3; * 22.1 versions prior to 22.1R3-S4; * 22.2 versions prior to 22.2R3; * 22.3 versions prior to 22.3R2-S2; * 22.4 versions prior to 22.4R2;