Recent CVEs
CVE-2023-6943
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
CVE-2023-6942
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.
CVE-2023-5275
Improper Input Validation vulnerability in simulation function of GX Works2 allows an attacker to cause a denial-of-service (DoS) condition on the function by sending specially crafted packets. However, the attacker would need to send the packets from within the same personal computer where the function is running.
CVE-2023-5274
Improper Input Validation vulnerability in simulation function of GX Works2 allows an attacker to cause a denial-of-service (DoS) condition on the function by sending specially crafted packets. However, the attacker would need to send the packets from within the same personal computer where the function is running.
CVE-2023-4088
Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder.
CVE-2022-29832
Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting.