Vulnerabilities

CVE-2017-9656

UNKNOWN

The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.

Published Apr 24, 2018

CVE-2017-9654

UNKNOWN

The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.

Published Apr 24, 2018

CVE-2018-5451

UNKNOWN

In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficiently proves that the claim is correct. This weakness can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or the ability to execute arbitrary code.

Published Mar 28, 2018

CVE-2018-7498

UNKNOWN

In Philips Alice 6 System version R8.0.2 or prior, the lack of proper data encryption passes up the guarantees of confidentiality, integrity, and accountability that properly implemented encryption conveys.

Published Mar 28, 2018

CVE-2018-5458

UNKNOWN

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability using SSL legacy encryption that could allow an attacker to gain unauthorized access to resources and information.

Published Mar 26, 2018

CVE-2018-5462

UNKNOWN

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an SSL incorrect hostname certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.

Published Mar 26, 2018

CVE-2018-5474

UNKNOWN

Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or cause the application to crash.

Published Mar 26, 2018

CVE-2018-5454

UNKNOWN

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime.

Published Mar 26, 2018

CVE-2018-5472

UNKNOWN

Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code.

Published Mar 26, 2018

CVE-2018-5468

UNKNOWN

Philips Intellispace Portal all versions 7.0.x and 8.0.x have a remote desktop access vulnerability that could allow an attacker to gain unauthorized access and in some cases escalate their level of privilege or execute arbitrary code

Published Mar 26, 2018

CVE-2018-5464

UNKNOWN

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an untrusted SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.

Published Mar 26, 2018

CVE-2018-5470

UNKNOWN

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an unquoted search path or element vulnerability that has been identified, which may allow an authorized local user to execute arbitrary code and escalate their level of privileges.

Published Mar 26, 2018

CVE-2018-5466

UNKNOWN

Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a self-signed SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.