CVE-2024-21915
CRITICALA privilege escalation vulnerability exists in Rockwell Automation FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and receive FTSP Administrator Group privileges. A threat actor could potentially read and modify sensitive data, delete data and render the FTSP system unavailable.
CVE-2024-21916
HIGHA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.
CVE-2023-27858
HIGHRockwell Automation Arena Simulation contains an arbitrary code execution vulnerability that could potentially allow a malicious user to commit unauthorized code to the software by using an uninitialized pointer in the application. The threat-actor could then execute malicious code on the system affecting the confidentiality, integrity, and availability of the product. The user would need to open a malicious file provided to them by the attacker for the code to execute.
CVE-2023-29464
HIGHFactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
CVE-2023-2262
CRITICALA buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.
CVE-2023-2917
CRITICALThe Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability. Due to an improper input validation, a path traversal vulnerability exists, via the filename field, when the ThinManager processes a certain function. If exploited, an unauthenticated remote attacker can upload arbitrary files to any directory on the disk drive where ThinServer.exe is installed. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and potentially gain remote code execution abilities.
CVE-2023-2915
HIGHThe Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, Due to improper input validation, a path traversal vulnerability exists when the ThinManager software processes a certain function. If exploited, an unauthenticated remote threat actor can delete arbitrary files with system privileges. A malicious user could exploit this vulnerability by sending a specifically crafted synchronization protocol message resulting in a denial-of-service condition.
CVE-2023-2914
HIGHThe Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, an integer overflow condition exists in the affected products. When the ThinManager processes incoming messages, a read access violation occurs and terminates the process. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and causing a denial of service condition in the software.
CVE-2023-2423
HIGHA vulnerability was discovered in the Rockwell Automation Armor PowerFlex device when the product sends communications to the local event log. Threat actors could exploit this vulnerability by sending an influx of network commands, causing the product to generate an influx of event log traffic at a high rate. If exploited, the product would stop normal operations and self-reset creating a denial-of-service condition. The error code would need to be cleared prior to resuming normal operations.
CVE-2023-3596
HIGHWhere this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.
CVE-2023-2072
HIGHThe Rockwell Automation PowerMonitor 1000 contains stored cross-site scripting vulnerabilities within the web page of the product. The vulnerable pages do not require privileges to access and can be injected with code by an attacker which could be used to leverage an attack on an authenticated user resulting in remote code execution and potentially the complete loss of confidentiality, integrity, and availability of the product.