Loading HuntDB...

Vulnerabilities

CVE-2018-13807

UNKNOWN

A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools.

Published Sep 12, 2018

CVE-2018-11456

UNKNOWN

A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.

Published Aug 07, 2018

CVE-2018-11453

UNKNOWN

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation.

Published Aug 07, 2018

CVE-2018-11455

UNKNOWN

A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4), Automation License Manager 6 (All versions < 6.0.1). A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or special conditions of the system, but user interaction is required.

Published Aug 07, 2018

CVE-2018-11454

UNKNOWN

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.

Published Aug 07, 2018

CVE-2018-11452

UNKNOWN

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published Jul 23, 2018

CVE-2018-11451

UNKNOWN

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published Jul 23, 2018

CVE-2018-11450

UNKNOWN

A reflected Cross-Site-Scripting (XSS) vulnerability has been identified in Siemens PLM Software TEAMCENTER (V9.1.2.5). If a user visits the login portal through the URL crafted by the attacker, the attacker can insert html/javascript and thus alter/rewrite the login portal page. Siemens PLM Software TEAMCENTER V9.1.3 and newer are not affected.

Published Jul 09, 2018

CVE-2018-4858

UNKNOWN

A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Published Jul 09, 2018

CVE-2018-4854

UNKNOWN

A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system.

Published Jul 03, 2018

CVE-2018-4853

UNKNOWN

A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device.

Published Jul 03, 2018

CVE-2018-4851

UNKNOWN

A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed.

Published Jul 03, 2018

CVE-2018-4856

UNKNOWN

A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users.

Published Jul 03, 2018

CVE-2018-4855

UNKNOWN

A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client configuration files and during network transmission could allow an attacker in a privileged position to obtain access passwords.

Published Jul 03, 2018

CVE-2018-4852

UNKNOWN

A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device.

Published Jul 03, 2018

CVE-2018-4845

UNKNOWN

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.

Published Jun 26, 2018

CVE-2018-4860

UNKNOWN

A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published Jun 26, 2018

CVE-2018-4859

UNKNOWN

A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published Jun 26, 2018

CVE-2018-11448

UNKNOWN

A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published Jun 26, 2018

CVE-2018-11449

UNKNOWN

A vulnerability has been identified in SCALANCE M875 (All versions). An attacker with access to the local file system might obtain passwords for administrative users. Successful exploitation requires read access to files on the local file system. A successful attack could allow an attacker to obtain administrative passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published Jun 26, 2018

CVE-2018-11447

UNKNOWN

A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published Jun 26, 2018

CVE-2018-4861

UNKNOWN

A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could potentially read and download arbitrary files from the device's file system. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Published Jun 26, 2018

CVE-2018-4850

UNKNOWN

A vulnerability has been identified in SIMATIC S7-400 (incl. F) CPU hardware version 4.0 and below (All versions), SIMATIC S7-400 (incl. F) CPU hardware version 5.0 (All firmware versions < V5.2), SIMATIC S7-400H CPU hardware version 4.5 and below (All versions). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart.

Published May 16, 2018

CVE-2018-4849

UNKNOWN

A vulnerability has been identified in Siveillance VMS Video for Android (All versions < V12.1a (2018 R1)), Siveillance VMS Video for iOS (All versions < V12.1a (2018 R1)). Improper certificate validation could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. The security vulnerability could be exploited by an attacker in a privileged network position which allows intercepting the communication channel between the affected app and a server (such as Man-in-the-Middle). Furthermore, an attacker must be able to generate a certificate that results for the validation algorithm in a checksum identical to a trusted certificate. Successful exploitation requires no user interaction. The vulnerability could allow reading data from and writing data to the encrypted communication channel between the app and a server, impacting the communication's confidentiality and integrity. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Published May 03, 2018

CVE-2018-4847

UNKNOWN

A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions < V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app's directory. Siemens provides mitigations to resolve the security issue.

Published Apr 23, 2018

CVE-2018-4841

UNKNOWN

A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it.

Published Mar 29, 2018

CVE-2018-4844

UNKNOWN

A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Published Mar 20, 2018

CVE-2018-4838

UNKNOWN

A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.

Published Mar 08, 2018

CVE-2018-4836

UNKNOWN

A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations.

Published Jan 25, 2018

CVE-2018-4835

UNKNOWN

A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.

Published Jan 25, 2018

CVE-2018-4837

UNKNOWN

A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with access to the TeleControl Server Basic's webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition.

Published Jan 25, 2018

CVE-2017-12736

UNKNOWN

A vulnerability has been identified in RUGGEDCOM ROS for RSL910 devices (All versions < ROS V5.0.1), RUGGEDCOM ROS for all other devices (All versions < ROS V4.3.4), SCALANCE XB-200/XC-200/XP-200/XR300-WG (All versions between V3.0 (including) and V3.0.2 (excluding)), SCALANCE XR-500/XM-400 (All versions between V6.1 (including) and V6.1.1 (excluding)). After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to writeto the device under certain conditions, potentially allowing users located in the adjacentnetwork of the targeted device to perform unauthorized administrative actions.

Published Dec 26, 2017

CVE-2017-6865

UNKNOWN

A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.

Published May 11, 2017

CVE-2016-9158

UNKNOWN

A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system.

Published Dec 17, 2016

CVE-2016-9159

UNKNOWN

A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.

Published Dec 17, 2016