Loading HuntDB...

Vulnerabilities

CVE-2018-1147

UNKNOWN

In Nessus before 7.1.0, a XSS vulnerability exists due to improper input validation. A remote authenticated attacker could create and upload a .nessus file, which may be viewed by an administrator allowing for the execution of arbitrary script code in a user's browser session. In other scenarios, XSS could also occur by altering variables from the Advanced Settings.

Published May 18, 2018

CVE-2018-1148

UNKNOWN

In Nessus before 7.1.0, Session Fixation exists due to insufficient session management within the application. An authenticated attacker could maintain system access due to session fixation after a user password change.

Published May 18, 2018

CVE-2018-1142

UNKNOWN

Tenable Appliance versions 4.6.1 and earlier have been found to contain a single XSS vulnerability. Utilizing a specially crafted request, an authenticated attacker could potentially execute arbitrary JavaScript code by manipulating certain URL parameters related to offline plugins.

Published Mar 28, 2018

CVE-2018-1141

UNKNOWN

When installing Nessus to a directory outside of the default location, Nessus versions prior to 7.0.3 did not enforce secure permissions for sub-directories. This could allow for local privilege escalation if users had not secured the directories in the installation location.

Published Mar 20, 2018

CVE-2017-11507

UNKNOWN

A cross site scripting (XSS) vulnerability exists in Check_MK versions 1.2.8x prior to 1.2.8p25 and 1.4.0x prior to 1.4.0p9, allowing an unauthenticated attacker to inject arbitrary HTML or JavaScript via the output_format parameter, and the username parameter of failed HTTP basic authentication attempts, which is returned unencoded in an internal server error page.

Published Dec 11, 2017

CVE-2017-11508

UNKNOWN

SecurityCenter versions 5.5.0, 5.5.1 and 5.5.2 contain a SQL Injection vulnerability that could be exploited by an authenticated user with sufficient privileges to run diagnostic scans. An attacker could exploit this vulnerability by entering a crafted SQL query into the password field of a diagnostic scan within SecurityCenter. Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access.

Published Nov 02, 2017

CVE-2017-11506

UNKNOWN

When linking a Nessus scanner or agent to Tenable.io or other manager, Nessus 6.x before 6.11 does not verify the manager's TLS certificate when making the initial outgoing connection. This could allow man-in-the-middle attacks.

Published Aug 09, 2017