Vulnerabilities
CVE-2024-4115
HIGHA vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4114
HIGHA vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4113
HIGHA vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4112
HIGHA vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4111
HIGHA vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4066
HIGHA vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4065
HIGHA vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4064
HIGHA vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-33213
MEDIUMTenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic.
CVE-2024-33215
CRITICALTenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/addressNat.
CVE-2024-33214
HIGHTenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter in ip/goform/RouteStatic.
CVE-2024-33217
UNKNOWNTenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parameter in ip/goform/addressNat.
CVE-2024-33212
UNKNOWNTenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm.
CVE-2024-4020
HIGHA vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromAddressNat of the file /goform/addressNat. The manipulation of the argument entrys leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3910
HIGHA vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3909
HIGHA vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3908
MEDIUMA vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3907
HIGHA vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3906
HIGHA vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3905
HIGHA vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-32318
CRITICALTenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function.
CVE-2024-32312
MEDIUMTenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function.
CVE-2024-32310
HIGHTenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function.
CVE-2024-32291
HIGHTenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function.
CVE-2024-32299
HIGHTenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
CVE-2024-32292
HIGHTenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
CVE-2024-32316
UNKNOWNTenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.
CVE-2024-32303
HIGHTenda AC15 v15.03.20_multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-32290
MEDIUMTenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function.
CVE-2024-32288
MEDIUMTenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function.
CVE-2024-32313
MEDIUMTenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the adslPwd parameter of the formWanParameterSetting function.
CVE-2024-32286
CRITICALTenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVirtualSer function.
CVE-2024-32302
MEDIUMTenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
CVE-2024-32317
UNKNOWNTenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32285
HIGHTenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function.
CVE-2024-32307
UNKNOWNTenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-32306
MEDIUMTenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-32283
HIGHTenda FH1203 V2.0.1.6 firmware has a command injection vulnerablility in formexeCommand function via the cmdinput parameter.
CVE-2024-32315
MEDIUMTenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32311
MEDIUMTenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32305
HIGHTenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-32301
CRITICALTenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
CVE-2024-32320
MEDIUMTenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function.
CVE-2024-32281
HIGHTenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter.
CVE-2024-32287
MEDIUMTenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function.
CVE-2023-46060
HIGHA Buffer Overflow vulnerability in Tenda AC500 v.2.0.1.9 allows a remote attacker to cause a denial of service via the port parameter at the goform/setVlanInfo component.
CVE-2024-32282
MEDIUMTenda FH1202 v1.2.0.14(408) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
CVE-2024-32293
HIGHTenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function.
CVE-2024-32314
LOWTenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
CVE-2024-3882
HIGHA vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.