Loading HuntDB...

Version 15.03.05.05

OTHER 17 CVEs

Known Vulnerabilities

CVE-2024-10280

A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

UNKNOWN CVSS 6.5 Published Oct 23, 2024

CVE-2024-30891

A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution.

UNKNOWN CVSS 8.8 Published Apr 05, 2024

CVE-2024-28551

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the ssid parameter of form_fast_setting_wifi_set function.

UNKNOWN CVSS 7.5 Published Mar 26, 2024

CVE-2024-28545

Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload function.

UNKNOWN CVSS 9.8 Published Mar 26, 2024

CVE-2024-2854

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

MEDIUM CVSS 6.3 Published Mar 24, 2024

CVE-2024-28550

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the filePath parameter of formExpandDlnaFile function.

UNKNOWN CVSS 4.3 Published Mar 18, 2024

CVE-2024-28537

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function.

UNKNOWN CVSS 9.8 Published Mar 18, 2024

CVE-2024-28547

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the firewallEn parameter of formSetFirewallCfg function.

UNKNOWN CVSS 6.5 Published Mar 18, 2024

CVE-2024-2560

A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

MEDIUM CVSS 4.3 Published Mar 17, 2024

CVE-2024-2558

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 17, 2024

CVE-2024-2547

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 17, 2024

CVE-2024-2490

A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 15, 2024

CVE-2024-2488

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 15, 2024

CVE-2024-2487

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 15, 2024

CVE-2024-2485

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 15, 2024

CVE-2024-28535

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.

HIGH CVSS 8.0 Published Mar 12, 2024

CVE-2024-28553

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function.

UNKNOWN CVSS 9.8 Published Mar 12, 2024