Loading HuntDB...

Version 2.0.1.6

OTHER 19 CVEs

Known Vulnerabilities

CVE-2024-32299

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.

HIGH CVSS 8.8 Published Apr 17, 2024

CVE-2024-32311

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.

MEDIUM CVSS 6.5 Published Apr 17, 2024

CVE-2024-30607

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function.

HIGH CVSS 8.0 Published Mar 28, 2024

CVE-2024-30599

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function.

HIGH CVSS 8.8 Published Mar 28, 2024

CVE-2024-30597

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security parameter of the formWifiBasicSet function.

MEDIUM CVSS 6.5 Published Mar 28, 2024

CVE-2024-30598

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security_5g parameter of the formWifiBasicSet function.

UNKNOWN CVSS 6.5 Published Mar 28, 2024

CVE-2024-30606

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the page parameter of the fromDhcpListClient function.

UNKNOWN CVSS 8.0 Published Mar 28, 2024

CVE-2024-30601

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function.

HIGH CVSS 8.0 Published Mar 28, 2024

CVE-2024-30600

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function.

UNKNOWN CVSS 8.0 Published Mar 28, 2024

CVE-2024-30603

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the urls parameter of the saveParentControlInfo function.

UNKNOWN CVSS 6.5 Published Mar 28, 2024

CVE-2024-30604

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the list1 parameter of the fromDhcpListClient function.

UNKNOWN CVSS 7.5 Published Mar 28, 2024

CVE-2024-2994

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 27, 2024

CVE-2024-2993

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been classified as critical. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 27, 2024

CVE-2024-2992

A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 27, 2024

CVE-2024-2991

A vulnerability has been found in Tenda FH1203 2.0.1.6 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

MEDIUM CVSS 6.3 Published Mar 27, 2024

CVE-2024-2990

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258159. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 27, 2024

CVE-2024-2989

A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 27, 2024

CVE-2024-2988

A vulnerability classified as critical was found in Tenda FH1203 2.0.1.6. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258157 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH CVSS 8.8 Published Mar 27, 2024

CVE-2024-2977

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.