Loading HuntDB...

i21

2 Versions 14 CVEs

Recent CVEs

CVE-2024-4497

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH May 05, 2024

CVE-2024-4496

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH May 05, 2024

CVE-2024-4495

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH May 05, 2024

CVE-2024-4492

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH May 05, 2024

CVE-2024-4251

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH Apr 27, 2024

CVE-2024-4250

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH Apr 27, 2024

CVE-2024-4249

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH Apr 27, 2024

CVE-2024-4248

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH Apr 27, 2024

CVE-2024-4247

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH Apr 27, 2024

CVE-2024-4245

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

HIGH Apr 27, 2024